Home > Allen Bradley > Allen Bradley Servo Error Codes

Allen Bradley Servo Error Codes

Contents

Code Name Type Description CP-02 Bckgnd scheduler fault Hard Internal Processor error detected CP-04 Interrupt Timeout Hard Internal Processor error detected CP-05 Logic power supply loss Soft 5V or +12V logic Drives Service & Support General Resources Drives Service & Support > 1395 > Fault Codes Available sections: SP Processor Faults VP Processor Faults CP Processor Faults Discreet Adapter Boards In general, most System Processor faults indicate that an internal processor error somwhere in the 1395 system has occured. ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.5/ Connection to 0.0.0.5 failed. his comment is here

In some cases, you can test a new motor without installing it, by powering the machine down, and connecting the new motor, then power up and see if you can operate If problems persist after attempting to troubleshoot the system, please contact your Rockwell Automation sales representative for further assistance. No Type is associated with these faults. The system returned: (22) Invalid argument The remote host or network may be down. http://www.ab.com/support/abdrives/1395/faults.html

Allen Bradley Servo Drive Fault Codes

Power (PWR) indicator is ON, but seven-segment status indicator is OFF. The system returned: (22) Invalid argument The remote host or network may be down. Generated Thu, 17 Nov 2016 23:33:24 GMT by s_hp106 (squid/3.5.20) Kinetix drives have no Torque overload fault although you can set a torque limit.

The person who wired it did not know that the motor shield should of been grounded on the drive casing it was removed at the electrical pannel entrance as well as Can it be because they have the torque O/L limit set too high in the PLC limits? Is this an absolute servo? Allen Bradley Servo Motor Troubleshooting If you trend the torque versus the position command and position error, you'll see this happen.

The digital reference adapter provides an interface between external devices and the 1395 main Control Board. Thanks. Error is E19.. When I start the machine the hub reverses briefly then goes forward(this has not happened in the past)and faults:huh:.

All Ultra3000 drives Flashing E followed by two numbers Your Ultra3000 drive has an error. Kinetix 6000 E19 Fault Proceed to the section Error Codes below. Verify that the external +5V auxiliary power supply (as measured at the drive terminals) reads between 5.10V and 5.25V. Generated Thu, 17 Nov 2016 23:33:24 GMT by s_hp106 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection

Allen Bradley Ultra 3000 Error Codes

If that doesn't help replace the cable. I don't like to replace parts unless I have proof of the exact root cause, but this is one of the exceptions, where it's (usually) easier and faster to diagnose it Allen Bradley Servo Drive Fault Codes Error Code Problem or Symptom Possible Cause Action/Solution Power (PWR) indicator not ON No ac power or auxiliary logic power. Kinetix 6500 Fault Codes Your cache administrator is webmaster.

Digital I/O not working correctly I/O power supply disconnected. http://missioncritiallinux.com/allen-bradley/allen-bradley-panelview-error-codes.html Code Name Type Description VP-10 Feedback Loss Sel Velocity Fdbk < Tach Loss Vel & CEMF > Tach Loss CEMF VP-12 Absolute overspeed Soft Motor velocity exceeds max speed limits VP-13 Seven-segment Status Indicator Error Codes Ultra3000 Drives with the Logic Power Status Indicator ON Status Indicator Then 2098-DSD-xxx, 2098-DSD-xxxX, 2098-DSD-HVxxx, or 2098-DSD-HVxxxX Actively cycling segments in a full circle Your Ultra3000 The drive will drive up to the torque limit and hold there if there is no position command to trip the position error (actual vs. Allen Bradley Ultraware

LED Name Color Function DS1 Green +12 V Supply Operational DS2 Green -12 V Supply Operational DS3 Green Processor Functional DS4 Green External 24 V Supply Functional DSI1 Green Digital In Internal power supply malfunction. Please try the request again. weblink Your cache administrator is webmaster.

Drive will only hold motor in position if the servo is commanded on and I believe a fault will disable the servo and release the motor. Allen Bradley Ultra 3000 Error Code E19 keithkyllNovember 28th, 2009, 02:04 PM...When I start the machine the hub reverses briefly...It moves backwards because it's out of phase. If the system was modified recently, has anyone tried a re-tune of the servo loop?

Sometimes even after swapping out like-for-like motors, I've had to retune.

the encoder cable was also checked for continuity from the servo to the break out box. Code Name Description NA-01 Node Adapter Processor OK Indicates no faults are present, the adapter is functional NA-06 Handshake Timeout Communication failed between Adapter and Main Control Board NA-08 No COMSOF gmfergNovember 28th, 2009, 05:28 PMNoise could definitely be an issue. Allen Bradley Ultra3000 Drive Manual Make sure the motor cable shield is clamped to the drive as shown in the manual.

Please try the request again. This includes monitoring the armature and field currents to the motor, power components, incoming synchronization, and communications to the VP. It lasted about 6 weeks. . http://missioncritiallinux.com/allen-bradley/allen-bradley-controlnet-error-codes.html You have not mentioned whether you've checked the phase wiring.